• Does chronic occupational exposure to volatile anesthetic agents influence the rate of neutrophil apoptosis?

      Goto, Y; Gallagher, J; Fanning, N; Wang, J; McCusker, S; Redmond, P; Shorten, G; Department of Anaesthesia and Intensive Care Medicine, Cork University Hospital, , University College Cork, Ireland. (2012-02-03)
      PURPOSE: The purpose of this preliminary investigation was to determine whether the rate of neutrophil apoptosis in health care workers is influenced by exposure to volatile anesthetic agents. METHODS: Percentage neutrophil apoptosis (Annexin-V FITC assay) was measured in health care workers (n = 20) and unexposed volunteers (n = 10). For the health care workers, time weighted personal exposure monitoring to N2O, sevoflurane and isoflurane was carried out. RESULTS: The sevoflurane and isoflurane concentrations to which health care workers were exposed were less than recommended levels in all 20 cases. Percent apoptosis was less at 24 (but not at one and 12) hr culture in health care workers [50.5 (9.7)%; P = 0.008] than in unexposed volunteers [57.3 (5.1)%]. CONCLUSION: Inhibition of neutrophil apoptosis at 24 hr culture was demonstrated in health care workers chronically exposed to volatile anesthetic agents. Exposure was well below recommended levels in the both scavenged and unscavenged work areas in which the study was carried out. Further study is required to assess the effect of greater degrees of chronic exposure to volatile anesthetic agents on neutrophil apoptosis.
    • Universal precautions--do Irish anaesthetists comply?

      O'Rourke, N; Bennett, M; Porter, J; Gallagher, D J; Shorten, G; Department of Anaesthesia and Intensive Care Medicine, Medicine, Cork University , Hospital, Cork. (2012-02-03)
      BACKGROUND: Anaesthetists are at high risk from blood-borne pathogens. Universal Precautions (UP) include the routine use of appropriate barrier precautions and techniques to reduce the likelihood of exposure to blood, body fluids and tissues that may contain pathogens. The compliance of Irish anaesthetists with these precautions has not been studied. AIM: To study the attitudes of Irish anaesthetists to Universal Precautions. METHOD: A postal questionnaire was sent to 210 anaesthetists currently practising in Ireland. The questionnaire was based on a model used in Australia and New Zealand. RESULTS: There was a 50% response rate to the survey. Only 15% of respondents had taken a risk history from a patient in the preceding four weeks. Resheathing of needles was commonplace. The effectiveness of hepatitis B immunisation was rarely checked and only 66% of respondents believe implementation of Universal Precautions to be practical. CONCLUSION: Irish anaesthetists comply poorly with Universal Precautions.